Search Results (2336 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-59086 1 Siemens 1 Simcenter Nastran 2026-08-13 7.8 High
A vulnerability has been identified in Simcenter Femap (All versions < V2606), Simcenter Nastran (All versions < V2606). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process.
CVE-2026-58115 1 Siemens 1 Simatic Iot2050 2026-08-13 10 Critical
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4.1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.
CVE-2026-59693 1 Siemens 5 Desigo Dxr2, Desigo Pxc3, Desigo Pxc4 and 2 more 2026-08-13 4.3 Medium
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.233.16-7862), Desigo PXC3 (All versions < V01.21.233.16-7862), Desigo PXC4 (All versions < V02.21.194.36-2715), Desigo PXC5.E003 (All versions < V02.21.194.36-2715), Desigo PXC5.E24 (All versions < V02.21.194.36-2715), Desigo PXC7 (All versions < V02.21.194.36-2715). The affected devices are vulnerable to a denial-of-service (DoS) vulnerability. An attacker can exploit this issue by sending a malformed BACnet packet, causing the device to stop responding to BACnet queries. Recovery requires a device reset or reboot to restore normal functionality.
CVE-2026-64629 1 Siemens 1 Parasolid 2026-08-13 7.8 High
A vulnerability has been identified in Parasolid V38.0 (All versions < V38.0.235), Parasolid V38.1 (All versions < V38.1.230). The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2026-69108 1 Siemens 1 Siemens License Server (sls) 2026-08-13 6 Medium
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.1). The affected application is vulnerable to a local privilege escalation due to an insecure sudoers policy. This could allow an attacker to execute arbitrary commands and plant malicious files as root, leading to full system compromise.
CVE-2026-69109 1 Siemens 1 Siemens License Server (sls) 2026-08-13 7.5 High
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.3). The affected application is vulnerable to a path traversal vulnerability due to lack of sanitization of user input. This could allow a remote attacker to access arbitrary files on the application.
CVE-2026-59700 1 Siemens 1 Simcenter Femap 2026-08-12 7.8 High
A vulnerability has been identified in Simcenter Femap (All versions < V2606.0001). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CVE-2026-57262 1 Siemens 1 Logo! Soft Comfort 2026-08-12 6.8 Medium
A vulnerability has been identified in LOGO! Soft Comfort (All versions < V9). Affected products use a static, hardcoded AES master key to encrypt project files. This could allow a local attacker to extract the master key from the application files or memory and use it to decrypt project files or remove project passwords entirely without knowing the actual user-defined password.
CVE-2026-57263 1 Siemens 1 Logo! Soft Comfort 2026-08-12 6.8 Medium
A vulnerability has been identified in LOGO! Soft Comfort (All versions < V9). The project password feature in the affected products stores the password as an unsalted SHA-256 hash. This could allow an attacker who has obtained the project file to perform efficient offline dictionary or brute-force attacks against the unsalted hash.
CVE-2026-59701 1 Siemens 1 Simcenter Femap 2026-08-11 7.8 High
A vulnerability has been identified in Simcenter Femap (All versions < V2606.0001). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CVE-2021-42059 2 Insyde, Siemens 29 Insydeh2o, Simatic Field Pg M5, Simatic Field Pg M5 Firmware and 26 more 2026-08-11 6.7 Medium
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver.
CVE-2021-41838 2 Insyde, Siemens 29 Insydeh2o, Simatic Field Pg M5, Simatic Field Pg M5 Firmware and 26 more 2026-08-11 8.2 High
An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check.
CVE-2021-41837 2 Insyde, Siemens 29 Insydeh2o, Simatic Field Pg M5, Simatic Field Pg M5 Firmware and 26 more 2026-08-11 8.2 High
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
CVE-2021-33626 2 Insyde, Siemens 33 Insydeh2o, Ruggedcom Apr1808, Ruggedcom Apr1808 Firmware and 30 more 2026-08-11 7.8 High
A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.
CVE-2021-33625 3 Insyde, Netapp, Siemens 34 Insydeh2o, Fas\/aff Bios, Ruggedcom Ape1808 and 31 more 2026-08-11 7.5 High
An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
CVE-2020-27339 2 Insyde, Siemens 33 Insydeh2o, Ruggedcom Apr1808, Ruggedcom Apr1808 Firmware and 30 more 2026-08-11 6.7 Medium
In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5).
CVE-2024-49894 3 Debian, Linux, Siemens 5 Debian Linux, Linux Kernel, Simatic S7-1500 Tm Mfp and 2 more 2026-08-04 7.1 High
In the Linux kernel, the following vulnerability has been resolved: drm/amd/display: Fix index out of bounds in degamma hardware format translation Fixes index out of bounds issue in `cm_helper_translate_curve_to_degamma_hw_format` function. The issue could occur when the index 'i' exceeds the number of transfer function points (TRANSFER_FUNC_POINTS). The fix adds a check to ensure 'i' is within bounds before accessing the transfer function points. If 'i' is out of bounds the function returns false to indicate an error. Reported by smatch: drivers/gpu/drm/amd/amdgpu/../display/dc/dcn10/dcn10_cm_common.c:594 cm_helper_translate_curve_to_degamma_hw_format() error: buffer overflow 'output_tf->tf_pts.red' 1025 <= s32max drivers/gpu/drm/amd/amdgpu/../display/dc/dcn10/dcn10_cm_common.c:595 cm_helper_translate_curve_to_degamma_hw_format() error: buffer overflow 'output_tf->tf_pts.green' 1025 <= s32max drivers/gpu/drm/amd/amdgpu/../display/dc/dcn10/dcn10_cm_common.c:596 cm_helper_translate_curve_to_degamma_hw_format() error: buffer overflow 'output_tf->tf_pts.blue' 1025 <= s32max
CVE-2026-54798 1 Siemens 2 Cpci85 Central Processing\/communication, Sicore Base System 2026-08-01 6.5 Medium
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0). The affected application includes a debugging interface that is accessible through HTTP endpoints. This could allow an authenticated attacker to disrupt the system by crashing the web process causing denial of service conditions.
CVE-2026-54799 1 Siemens 2 Cpci85 Central Processing\/communication, Sicore Base System 2026-08-01 6.7 Medium
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0). The affected application contains a vulnerability in its firmware update mechanism's signature validation process. This could allow an attacker to install malicious firmware, leading to persistent code execution and system compromise.
CVE-2026-54800 1 Siemens 2 Cpci85 Central Processing\/communication, Sicore Base System 2026-08-01 4.8 Medium
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0). The affected application ships with a default configuration that disables all OPC UA security mechanisms. This could allow an attacker to gain unauthorized access and control over critical system functions.