| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Baker Hughes – Bently Nevada 3500 System TDI Firmware version 5.05
contains a vulnerability in their password retrieval functionality which could allow an attacker to access passwords stored on the device. |
|
Santesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process. |
|
Sante DICOM Viewer Pro lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.
|
|
Sante DICOM Viewer Pro lacks proper validation of user-supplied data when parsing DICOM files. This could lead to a stack-based buffer overflow. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.
|
|
In Weintek's cMT3000 HMI Web CGI device, an anonymous attacker can execute arbitrary commands after login to the device.
|
|
The application interface allows users to perform certain actions via
HTTP requests without performing any validity checks to verify the
requests. This can be exploited to perform certain actions with
administrative privileges if a logged-in user visits a malicious web
site.
|
|
Sielco PolyEco1000 is vulnerable to a session hijack vulnerability due to the cookie being vulnerable to a brute force attack, lack of SSL, and the session being visible in requests.
|
|
Sielco PolyEco1000 is vulnerable to an information disclosure vulnerability due to improper access control enforcement. An unauthenticated remote attacker can exploit this via a specially crafted request to gain access to sensitive information.
|
|
Sielco PolyEco1000 is vulnerable to an attacker bypassing authorization and accessing resources behind protected pages. The application interface allows users to perform certain actions via HTTP requests without performing any validity checks to verify the requests.
|
|
Sielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages.
|
|
The Crimson 3.2 Windows-based configuration tool allows users with administrative access to define new passwords for users and to download the resulting security configuration to a device. If such a password contains the percent (%) character, invalid values will be included, potentially truncating the string if a NUL is encountered. If the simplified password is not detected by the administrator, the device might be left in a vulnerable state as a result of more-easily compromised credentials. Note that passwords entered via the Crimson system web server do not suffer from this vulnerability.
|
| Zavio CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220,
CB6231, B8520, B8220, and CD321
IP Cameras
with firmware version M2.1.6.05 has a
command injection vulnerability in their implementation of their
binaries and handling of network requests.
|
| Zavio CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220,
CB6231, B8520, B8220, and CD321 IP Cameras
with firmware version M2.1.6.05 are
vulnerable to stack-based overflows. During the process of updating
certain settings sent from incoming network requests, the product does
not sufficiently check or validate allocated buffer size. This may lead
to remote code execution.
|
| A security issue was discovered in ingress-nginx where a user that can create or update ingress objects can use a newline character to bypass the sanitization of the `spec.rules[].http.paths[].path` field of an Ingress object (in the `networking.k8s.io` or `extensions` API group) to obtain the credentials of the ingress-nginx controller. In the default configuration, that credential has access to all secrets in the cluster. |
| Windows workloads can run as ContainerAdministrator even when those workloads set the runAsNonRoot option to true. |
| Path Traversal in Ivanti Avalanche before version 6.4.7 allows a remote unauthenticated attacker to bypass authentication. This CVE addresses incomplete fixes from CVE-2024-47010. |
| Path Traversal in Ivanti Avalanche before version 6.4.7 allows a remote unauthenticated attacker to leak sensitive information. This CVE addresses incomplete fixes from CVE-2024-47011. |
| Path Traversal in Ivanti Avalanche before version 6.4.7 allows a remote unauthenticated attacker to bypass authentication. |
| This vulnerability enables ssh access to minikube container using a default password. |
| OS command injection vulnerability in the download page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to execute an arbitrary OS command. |