Search Results (2538 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2025-4395 2026-04-15 6.8 Medium
Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025
CVE-2025-24375 2026-04-15 5 Medium
Charmed MySQL K8s operator is a Charmed Operator for running MySQL on Kubernetes. Before revision 221, the method for calling a SQL DDL or python based mysql-shell scripts can leak database users credentials. The method mysql-operator calls mysql-shell application rely on writing to a temporary script file containing the full URI, with user and password. The file can be read by a unprivileged user during the operator runtime, due it being created with read permissions (0x644). On other cases, when calling mysql cli, for one specific case when creating the operator users, the DDL contains said users credentials, which can be leak through the same mechanism of a temporary file. All versions prior to revision 221 for kubernetes and revision 338 for machine operators.
CVE-2024-28744 1 Furunosystems 2 Acera 9010-08 Firmware, Acera 9010-24 Firmware 2026-04-15 8.8 High
The password is empty in the initial configuration of ACERA 9010-08 firmware v02.04 and earlier, and ACERA 9010-24 firmware v02.04 and earlier. An unauthenticated attacker may log in to the product with no password, and obtain and/or alter information such as network configuration and user information. The products are affected only when running in non MS mode with the initial configuration.
CVE-2024-27143 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 9.8 Critical
Toshiba printers use SNMP for configuration. Using the private community, it is possible to remotely execute commands as root on the remote printer. Using this vulnerability will allow any attacker to get a root access on a remote Toshiba printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point. https://www.toshibatec.com/contacts/products/ As for the affected products/models/versions, see the reference URL.
CVE-2024-3624 1 Redhat 1 Mirror Registry 2026-04-15 7.3 High
A flaw was found in how Quay's database is stored in plain-text in mirror-registry on the jinja's config.yaml file. This flaw allows a malicious actor with access to this file to gain access to Quay's database.
CVE-2022-38695 2026-04-15 7.8 High
In BootRom, there's a possible unchecked command index. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2025-3920 2026-04-15 N/A
A vulnerability was identified in SUR-FBD CMMS where hard-coded credentials were found within a compiled DLL file. These credentials correspond to a built-in administrative account of the software. An attacker with local access to the system or the application's installation directory could extract these credentials, potentially leading to a complete compromise of the application's administrative functions. This issue was fixed in version 2025.03.27 of the SUR-FBD CMMS software.
CVE-2025-0936 2026-04-15 6.5 Medium
On affected platforms running Arista EOS with a gNMI transport enabled, running the gNOI File TransferToRemote RPC with credentials for a remote server may cause these remote-server credentials to be logged or accounted on the local EOS device or possibly on other remote accounting servers (i.e. TACACS, RADIUS, etc).
CVE-2025-15151 1 Talelin 1 Lin-cms 2026-04-15 3.7 Low
A vulnerability was determined in TaleLin Lin-CMS up to 0.6.0. This affects an unknown part of the file /tests/config.py of the component Tests Folder. This manipulation of the argument username/password causes password in configuration file. The attack is possible to be carried out remotely. The complexity of an attack is rather high. It is indicated that the exploitability is difficult. The exploit has been publicly disclosed and may be utilized.
CVE-2024-3625 1 Redhat 1 Mirror Registry 2026-04-15 7.3 High
A flaw was found in Quay, where Quay's database is stored in plain text in mirror-registry on Jinja's config.yaml file. This issue leaves the possibility of a malicious actor with access to this file to gain access to Quay's Redis instance.
CVE-2025-6949 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2025-6894 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in the API authorization logic of the affected device allows an authenticated, low-privileged user to execute the administrative `ping` function, which is restricted to higher-privileged roles. This vulnerability enables the user to perform internal network reconnaissance, potentially discovering internal hosts or services that would otherwise be inaccessible. Repeated exploitation could lead to minor resource consumption. While the overall impact is limited, it may result in some loss of confidentiality and availability on the affected device. There is no impact on the integrity of the device, and the vulnerability does not affect any subsequent systems.
CVE-2025-2343 2026-04-15 7.5 High
A vulnerability classified as critical was found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this vulnerability is an unknown functionality of the component Device Pairing. The manipulation leads to hard-coded credentials. Access to the local network is required for this attack to succeed. The complexity of an attack is rather high. The exploitation appears to be difficult. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-12650 2026-04-15 5.4 Medium
An attacker with low privileges can manipulate the requested memory size, causing the application to use an invalid memory area. This could lead to a crash of the application but it does not affected other applications.
CVE-2025-6893 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in broken access control has been identified in the /api/v1/setting/data endpoint of the affected device. This flaw allows a low-privileged authenticated user to call the API without the required permissions, thereby gaining the ability to access or modify system configuration data. Successful exploitation may lead to privilege escalation, allowing the attacker to access or modify sensitive system settings. While the overall impact is high, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2025-24331 2026-04-15 6.4 Medium
The Single RAN baseband OAM service is intended to run as an unprivileged service. However, it initially starts with root privileges and assigns certain capabilities before dropping to an unprivileged level. The capabilities retained from the root period are considered extensive after the privilege drop and, in theory, could potentially allow actions beyond the intended scope of the OAM service. These actions could include gaining root privileges, accessing root-owned files, modifying them as the file owner, and then returning them to root ownership. This issue has been corrected starting from release 24R1-SR 0.2 MP and later. Beginning with release 24R1-SR 0.2 MP, the OAM service software capabilities are restricted to the minimum necessary.
CVE-2024-45775 1 Redhat 2 Enterprise Linux, Openshift 2026-04-15 5.2 Medium
A flaw was found in grub2 where the grub_extcmd_dispatcher() function calls grub_arg_list_alloc() to allocate memory for the grub's argument list. However, it fails to check in case the memory allocation fails. Once the allocation fails, a NULL point will be processed by the parse_option() function, leading grub to crash or, in some rare scenarios, corrupt the IVT data.
CVE-2024-11630 1 E-lins 9 H685, H685f, H700 and 6 more 2026-04-15 7.3 High
A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way.