| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Tattile Smart+, Vega, and Basic device families firmware versions 1.181.5 and prior ship with default credentials that are not forced to be changed during installation or commissioning. An attacker who can reach the management interface can authenticate using the default credentials and gain administrative access, enabling unauthorized access to device configuration and data. |
| SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 contain a default credentials vulnerability that allows remote attackers to obtain administrative access to the management interface. Attackers can authenticate using the hardcoded default credentials without password change enforcement to gain full administrative control of the device. |
| OpenMQ exposes a TCP-based management service (imqbrokerd) that by default requires
authentication. However, the product ships with a default administrative account (admin/
admin) and does not enforce a mandatory password change on first use. After the first
successful login, the server continues to accept the default password indefinitely without
warning or enforcement.
In real-world deployments, this service is often left enabled without changing the default
credentials. As a result, a remote attacker with access to the service port could authenticate
as an administrator and gain full control of the protocol’s administrative features. |
| Istio is an open platform to connect, manage, and secure microservices. Prior to 1.29.1, 1.28.5, and 1.27.8, a user of Istio is impacted if the JWKS resolver becomes unavailable or the fetch fails, exposing hardcoded defaults regardless of use of the RequestAuthentication resource. This vulnerability is fixed in 1.29.1, 1.28.5, and 1.27.8. |
| Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, might share same credentials for telnet service. Hash of the password can be retrieved through physical access to SPI connected memory.
For the telnet service to be enabled, the inserted SD card needs to have a folder with a specific name created.
Two products were tested, but since the vendor has not replied to reports, patching status remains unknown, as well as groups of devices and firmware ranges in which the same password is shared.
Newer firmware versions might be vulnerable as well. |
| All the Toshiba printers share the same hardcoded root password. As for the affected products/models/versions, see the reference URL. |
| IO-1020 Micro ELD uses a default WIFI password that could allow an adjacent attacker to connect to the device.
|
| Control-M/Agents use a kdb or PKCS#12 keystore by default, and the default keystore password is well known and documented.
An attacker with read access to the keystore could access sensitive data using this password. |
| COMMAX CVD-Axx DVR 5.1.4 contains weak default administrative credentials that allow remote password attacks and disclose RTSP stream. Attackers can exploit this by sending a POST request with the 'passkey' parameter set to '1234', allowing them to access the web control panel. |
| DASAN GPON ONU H660WM OS version H660WMR210825 Hardware version DS-E5-583-A1 was discovered to contain insecure default credentials in the modem's control panel. |
| Gardyn Home Kit firmware before master.619, Home Kit Mobile Application before 2.11.0, and Home Kit Cloud API before 2.12.2026 use weak default credentials for secure shell access. This may result in attackers gaining access to exposed Gardyn Home Kits. |
| A vulnerability in the Eclipse Vert.x toolkit causes a memory leak in TCP servers configured with TLS and SNI support. When processing an unknown SNI server name assigned the default certificate instead of a mapped certificate, the SSL context is erroneously cached in the server name map, leading to memory exhaustion. This flaw allows attackers to send TLS client hello messages with fake server names, triggering a JVM out-of-memory error. |
| Authentication credentials leakage vulnerability in Hitachi Ops Center Analyzer viewpoint.This issue affects Hitachi Ops Center Analyzer viewpoint: from 10.0.0-00 before 11.0.4-00. |
| BrightSign players running BrightSign OS series 4 prior to v8.5.53.1 or
series 5 prior to v9.0.166 use a default password that is guessable with
knowledge of the device information. The latest release fixes this
issue for new installations; users of old installations are encouraged
to change all default passwords. |
| A vulnerability was found in IROAD Dash Cam X5 up to 20250203. It has been rated as problematic. This issue affects some unknown processing of the component SSID. The manipulation leads to use of default credentials. The attack needs to be initiated within the local network. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| nginx-defender is a high-performance, enterprise-grade Web Application Firewall (WAF) and threat detection system engineered for modern web infrastructure. This is a configuration vulnerability affecting nginx-defender deployments. Example configuration files
config.yaml and docker-compose.yml contain default credentials (default_password: "change_me_please", GF_SECURITY_ADMIN_PASSWORD=admin123). If users deploy nginx-defender without changing these defaults, attackers with network access could gain administrative control, bypassing security protections. The issue is addressed in v1.5.0 and later. |
| JM-DATA ONU JF511-TV version 1.0.67 uses default credentials that allow attackers to gain unauthorized access to the device with administrative privileges. |
| A CWE-1392 “Use of Default Credentials” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The device exposes an FTP server with default and easy-to-guess admin credentials. A remote attacker capable of interacting with the FTP server could gain access and perform changes over resources exposed by the service such as configuration files where password hashes are saved or where network settings are stored. |
| Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics
Solution is only in scope of
this vulnerability when
installed on a NUC server. BD Synapsys™
Informatics Solution installed
on a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is
not in scope. |
| If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface
protected by authentication. If the default credentials are not changed,
an attacker can use public knowledge to access the device as an
administrator. |