| A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to an exposed debug interface on the localhost. This allows any local user to gain code execution as administrative application user. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The "DBTest" tool of SIMATIC RTLS Locating Manager does not properly enforce access restriction. This could allow an authenticated local attacker to extract sensitive information from memory. |
| A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices are using a predictable IP ID sequence number. This leaves the system susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack and eventually could allow an attacker to create a denial of service condition. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing. |
| A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), Desigo CC (All versions if access from Installed Clients to Desigo CC server is only allowed within highly protected zones). The affected server application fails to authenticate specific client requests. Modification of the client binary could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database via the event port (default: 4998/tcp) |
| A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.3), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.3). The web server interface of affected devices improperly processes incoming malformed HTTP traffic at high rate. This could allow an unauthenticated remote attacker to force the device entering the stop/defect state, thus creating a denial of service condition. |
| A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0012), Tecnomatix Plant Simulation V2404 (All versions < V2404.0001). The affected applications contain a type confusion vulnerability while parsing specially crafted MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22958) |
| A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems improperly handles memory buffers when parsing X.509 certificates.
This could allow an unauthenticated remote attacker to crash the network service. |
| A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4 6MD66 (All versions), SIPROTEC 4 6MD665 (All versions), SIPROTEC 4 7SA522 (All versions), SIPROTEC 4 7SA6 (All versions < V4.78), SIPROTEC 4 7SD5 (All versions < V4.78), SIPROTEC 4 7SD610 (All versions < V4.78), SIPROTEC 4 7SJ61 (All versions), SIPROTEC 4 7SJ62 (All versions), SIPROTEC 4 7SJ63 (All versions), SIPROTEC 4 7SJ64 (All versions), SIPROTEC 4 7SJ66 (All versions), SIPROTEC 4 7SS52 (All versions), SIPROTEC 4 7ST6 (All versions), SIPROTEC 4 7UM61 (All versions), SIPROTEC 4 7UM62 (All versions), SIPROTEC 4 7UT612 (All versions), SIPROTEC 4 7UT613 (All versions), SIPROTEC 4 7UT63 (All versions), SIPROTEC 4 7VE6 (All versions), SIPROTEC 4 7VK61 (All versions), SIPROTEC 4 7VU683 (All versions), SIPROTEC 4 Compact 7RW80 (All versions), SIPROTEC 4 Compact 7SD80 (All versions), SIPROTEC 4 Compact 7SJ80 (All versions), SIPROTEC 4 Compact 7SJ81 (All versions), SIPROTEC 4 Compact 7SK80 (All versions), SIPROTEC 4 Compact 7SK81 (All versions). Affected devices do not properly handle interrupted operations of file transfer. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the devices need to be restarted. |
| The affected applications contain an out of bounds read past the end of
an allocated structure while parsing specially crafted PDF files. This
could allow an attacker to execute code in the context of the current
process. |
| A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. |
| A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application uses a Content Security Policy that allows unsafe script execution methods. This could allow an attacker to execute unauthorized scripts, potentially leading to cross-site scripting attacks. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code. |
| A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to alter the local database which contains the application credentials. This allows an attacker to gain administrative application privileges. |
| A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification.
This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability. |
| A vulnerability has been identified in Mendix Encryption (All versions >= V10.0.0 < V10.0.2). Affected versions of the module define a specific hard-coded default value for the EncryptionKey constant, which is used in projects where no individual EncryptionKey was specified.
This could allow to an attacker to decrypt any encrypted project data, as the default encryption key can be considered compromised. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'Log Viewers' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute the 'tail' command with root privileges and disclose contents of all files in the filesystem. |
| A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions < V2506.0001), Simcenter System Architect (All versions < V2506.0001), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack. |
| A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.2), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.2). Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured. |